High-capacity used alternative for land drilling programs. Preliminary technical information available for qualified institutional buyers.
General overview of the asset based on preliminary technical information provided by the source. All data is subject to confirmation during the due diligence process.
Current status: under technical and documentary evaluation. No price is presented at this stage. Pricing information, once available and authorized, will be provided directly to qualified institutional buyers in the due diligence process.
The following information was provided by the source as part of the asset's commercial package. It is presented in full, including elements not yet confirmed, to maintain technical transparency with the institutional buyer.
| Mast Type | IDS 154 ft |
| Racking Capacity | 33,000 ft (5" DP) / 30,000 ft (5-1/2") |
| Hook Load | 1,400,000 lb |
| Structure Type | Box on Box, 30 ft |
| Clear Height | 22 ft |
| Load Rating | 1,400,000 lb Casing / Set Back 800,000 lb |
| Rig Walking System | Veristic System (Optional) |
| Pad Capacity | 150 ft × 40 ft, X/Y axes |
| Drawworks | National 1625-DE, 3,000 HP |
| Motors | 3 × GE 752, 1,000 HP each |
| Auxiliary Brake | Elmagco 7838 |
| Hoisting Capacity (14 lines) | 1,420,000 lb |
| Hoisting Capacity (12 lines) | 1,250,000 lb |
| Hoisting Capacity (10 lines) | 1,075,000 lb |
| Rotary Table | SJ Petro 37-1/2" hydraulic |
| Top Drive | NOV 650 ton, 1-1/2" |
| Iron Roughneck | Varco ST-80C |
| Hydraulic Catwalk | Forum |
| Pipe Handling | IAT Rotating Mouse Hole |
| Engines | 4 × Caterpillar 3512 |
| Diesel Capacity | 18,000 gallons |
| Generators | 4 × Kato 1,365 kW |
| SCR System | 4 × Omron Generator Bays |
| Mud Pumps | 3 × HH, 1,600 HP each |
| Fluid Ends / Delivery | 7,500 psi |
| Charging Pumps | 3 × 6×5, 60 HP |
| Trip Tank Pump | 4×3×13, 100 HP |
| Mud Mixing Pump | 6×8×14, 100 HP |
| Process Pits | 600 bbl · 4 comp. · 3 agitators |
| Suction Pit | 600 bbl · 4 comp. · 4 agitators |
| Trip Tank | 100 bbl · 1 comp. · 10 HP agitator |
| Shale Shakers | 3 × Brandt King Cobra, linear motion |
| Degasser | Brandt D-1000-C |
| Desander | NOV Brandt, 3 × 10" cones |
| Desander Pump | 6×8 centrifugal, 100 HP |
| Desilter | NOV, 20 × 4" cones |
| Desilter Pump | 6×8 centrifugal, 100 HP |
| Annular TBD | Pending confirmation |
| Single Ram TBD | Pending confirmation |
| Double Ram TBD | Pending confirmation |
| Accumulator | 6 stations / 180 gallons |
| Choke Manifold | 10,000 psi |
| Mud Gas Separator | Poor Boy Degasser |
| Drill Pipe TBD | Pending confirmation |
| Drill Collars TBD | Pending confirmation |
The technical and photographic information presented corresponds to the package currently provided by the asset's source. At this stage, the preliminary evaluation is based on the available specifications and the visual evidence provided.
The source has indicated that the next stage for a buyer with technical interest is the physical inspection of the equipment, during which configuration, mechanical condition, structural integrity, scope of supply, and other relevant technical elements may be verified.
ALLIANCE recommends that any purchase determination be made only after an independent inspection by the buyer's qualified technical personnel and the corresponding documentary and commercial validation.
Representative selection of the photographic package provided by the source. An expanded set is available in the full gallery.
Photographs were provided as part of the asset's commercial information. Their date, the current condition of the equipment, and their correspondence with the final sale scope must be confirmed during due diligence and inspection.
Cross-section of the current progress of the evaluation process. This section will be updated as documentary and technical validation of the asset advances.
Structured work path to ensure order, confidentiality and control at every stage of the evaluation.
ALLIANCE acts as a strategic linking and commercial coordination platform between institutional buyers and the parties presenting the asset.
ALLIANCE does not present itself as the owner, manufacturer, operator, certifying body, or independent appraiser of the equipment described on this page.
Ownership, the authority to dispose of the asset, technical condition, certifications, availability, price, and final scope must be confirmed during the due diligence process and through the corresponding contractual instruments.
Begin the technical review process for the asset or coordinate an on-site evaluation under the corresponding confidentiality terms.
The information contained on this page is preliminary and informational in nature and is based on materials provided by third parties. It does not constitute an offer, a promise of sale, a technical warranty, a certification, a valuation, or a contractual obligation.
The specifications, photographs, condition, location, availability, price, and scope of the equipment are subject to independent validation, inspection, and documentary confirmation by the parties involved.
ALLIANCE does not guarantee the accuracy, currency, or completeness of the information presented here and assumes no responsibility for decisions made solely on the basis of this content. Access to additional information, as well as physical inspection of the asset, is subject to the prior execution of the corresponding confidentiality agreements.